Inside the Coil: How AIRWORK Winds, Assembles and Tests a Solenoid Valve
Inside the Coil: How AIRWORK Winds, Assembles and Tests a Solenoid Valve
Copper, armature, seal: three stages on one floor, and the reason the coil is the part that decides whether the valve works.
Every solenoid valve is an argument between electricity and air, and the coil is where that argument is settled. Apply 24 volts and the coil pulls an armature; the armature moves a seal; the valve opens. Remove the current and a spring puts everything back. Nothing in the assembly matters more than the winding at its centre, and at AIRWORK that winding happens on the same floor as the assembly and the test bench that follow it.
Winding: the coil starts as wire
Productio coil incipit ex filo cupri et bobina plastica. Bobinae in gradus in armariis onerantur, et filum a machina ponitur — fusus post fusum, bobina post bobinam, nullum manus super filum inter eos. Involutio automatica non est celerior modo quo visitator videre potest; sed est magis repetibilis. Via fili, tensio qua trahitur, et punctum ubi involutio desinit a machina, non ab operatore manu, constituuntur, ita ut prima coil per turnum et ultima eodem modo fiant.
Linea involutoria. Bobinae in armariis progrediuntur; filum a machina dirigitur.
Ad caput involutorium, bobinae sub fusum ordinantur et filum eadem via omni ciclo ponitur.
Coniunctio: coil fit valva
Ab inrotatione, spira ad coniunctionem progrediuntur. Unaquaeque armaturam et manicam suam accipit, deinde simul cum sigillo, quod vere obsignabit, in corpus valvulae inseritur. In linea, capita prehensionis et collocationis partes in fixationes sublevant, et stationes eandem motum iterant eodem ordine — sublevare, orientare, inserere, premere — ut corpus valvulae quod ex ultima statione egreditur eadem sequentia construatur atque quod ante illud.

Linea coniunctionis. Spirae ex inrotatione ingrediuntur et ut corpora valvularum inserta egrediuntur.

Caput prehensionis et collocationis super fixationem spirae. Statio unum motum iterat, milies per turnum.
Examen: nihil egreditur sine lectione.
Examinatio est gradus qui decernit an spirae aedificium relinquere possint. Spirae perfectae in vasis ad bancum perveniunt, ductus iam aptati; unaquaeque ad metrum connectitur. Lectio in hoc metro est quae ab operatore inspicitur antequam spirae in cartonem ponantur. Est gradus lentus comparatione ad inrotationem, et ita manere voluitur.

A finished coil connected to the test meter. Every coil is measured, not sampled.
The part, as marked
The valve shown here carries its ratings on the body: DC24V, 7W, an operating voltage range of DC21.4V–26.4V, a 100% duty rating (100%ED) and an IP65 enclosure rating, with the CE mark. 100%ED means the coil is rated to stay energised continuously rather than intermittently — the difference between a coil that is switched a few times an hour and one that is held on all day.

DC24V, 7W, 100%ED, IP65, CE: the ratings are moulded into the coil body, not added to a datasheet.
Copia
Standard voltages ship from stock; coils wound to a customer's specification are quoted individually.
Watch the process
A 72-second film of the winding, assembly and test stages described above accompanies this note.